ASTM F2170-11 PDF

ASTM F2170-11 PDF

ASTM F formally recognizes the use of in situ probes as a means of conducting relative humidity testing. In fact, ASTM F represents a fundamental. Last previous edition approved in as. F DOI: / F/FA. 2 For referenced ASTM standards, visit the ASTM . ASTM F ASTM F RH (Relative Humidity) DOI: /F The ASTM F standard represents a fundamental change in how moisture is.

Author: Tukazahn Shahn
Country: Uzbekistan
Language: English (Spanish)
Genre: Finance
Published (Last): 28 April 2005
Pages: 445
PDF File Size: 5.66 Mb
ePub File Size: 20.42 Mb
ISBN: 589-1-68117-813-8
Downloads: 19766
Price: Free* [*Free Regsitration Required]
Uploader: Doulkis

All cables have easy-to-connect and fail-proof 35mm stereo connectors. Now is a good time to buy! This will NOT be valid for ASTM compliance, but can certainly provide a target timeline for schedule decisions or for choosing alternate adhesive or flooring options that might have higher moisture tolerances. Many contractors t2170-11 vapor barriers directly under the slab to slow moisture permeation. F21700-11 sensors must be calibrated no less than 30 days prior to use.

September 2, at 9: Is this acceptable or compromise the test?

In-situ f217011 moisture testing places sensors, or probes, inside the slab itself. Section 11 of ASTM F details the requirements of each report, including test hole location, dates and times of measurements, RH reading, temperature reading, and any other conditions that might impact the RH reading see section 11 for complete reporting requirements.

10 Guidelines for ASTM F Compliance

UPS peak season may cause delays. That being said, I have heard a couple atsm different methods people are using. In-situ probes deepen concrete moisture measurement. We offer cost efficient, simple solutions to measure moisture. These first five steps are all preparatory and should be done before any sensors or RH probes are installed.

  DESCARGAR LIBRO VUELTA PEDRO URDEMALES PDF

Be sure to familiarize yourself with ASTM F and choose the best concrete moisture test method for the job. Logically then, moisture levels at the bottom of a slab will read higher from those at the surface.

To check the calibration we offer calibration f2170-11 salts. And moisture can still be an issue at grade so concrete foundations must be designed to include proper moisture drainage.

Ligno-Tec RH Concrete Test Conforms to ASTM F

Sub-grade water vapor can permeate even well-mixed and applied slabs. This process requires time axtm quantifiable concrete moisture measurements to verify. In this way, in situ measurement provides a composite picture of overall slab moisture levels, and provides the data necessary to make business decisions regarding flooring installations.

Without it, even a well-dried and functioning foundation can end up with concrete slab moisture problems. Thanks for the question. The In-Situ Method Aatm probes deepen concrete moisture measurement. For extended reach, a cable up to 50ft long can be added. In-situ probe concrete testing: When concrete is mixed and poured, water vapor migrates from the bottom of the slab to the surface to evaporate.

  ANGKATAN PEMUDA INSAF PDF

10 Guidelines for ASTM F2170 Preparation and Testing

We recommend placing the serial number decal which also helps track certification of each sensor on the corresponding test hole on the mapped report. If longer sleeves are desired we sstm offer 3. June 9, at 1: The MVER is defined as the rate of water vapor emissions from the surface of concrete and is determined with the use of a desiccant material sealed to the slab surface for a specified time period, then measured.

Your email address will not be published. xstm

Concrete slab moisture is a major cause of concrete flooring failure. We have people who use the Rapid RH on shallow pours.

No pin alignment of the cable needs to be asfm. The instruments have proven to perform well in rough mill environments with day-to-day usage. At this point, if one test fails, they all fail.

Use our checklist to record and report the RH readings. June 8, at 1: As any professional knows, ASTM standards are established to help guide industry testing and also to help ensure standardized best practices to protect both the installer and the consumer. Depress SET Button to check settings.